You are here

CMC in field "photometry and radiometry"

Quantity: Luminous intensity
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
(1 - 1.0E+4) cd (0.9 - 0.8) %
  • Correlated colour temperature (2000 up to 2856) K
818-MP-C811
(1 - 1.0E+4) cd (0.8 - 0.9) %
  • Correlated color temperature (2856 up to 3200) K
818-MP-C811
17 (1 - 2.0E+4) cd (0.8 - 0.8) % 818-MP-C811
Quantity: Illuminance responsivity, tungsten source
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
(- - -) A/lx (0.9 - 0.8) %
  • Illuminance (0.1 up to 10) lx
  • Correlated colour temperature 2856 K
818-MP-C811
(- - -) A/lx (0.8 - 0.8) %
  • Illuminance (10 up to 1000) lx
  • Correlated colour temperature 2856 K
818-MP-C811
(- - -) A/lx (0,8 - 1,2) %
  • Illuminance (1000 up to 30000) lx
  • Correlated colour temperature 2856 K
818-MP-C811
Quantity: Luminous flux
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
(10 - 3.0E+4) lm (0,9 - 1,5) %
  • Correlated colour temperature (2000 up to 3200) K
818-MP-C807
19 (10 - 2.0E+4) lm (1 - 1) % 818-MP-C807
Quantity: Illuminance
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
(0.1 - 10) lx (0,9 - 0,8) %
  • Correlated colour temperature (2000 up to 3200) K
818-MP-C811
(10 - 1000) lx (0,8 - 0,8) %
  • Correlated colour temperature (2000 up to 3200) K
(1000 - 3.0E+4) lx (0,8 - 1,2) %
  • Correlated colour temperature (2000 up to 3200) K
818-MP-C811
6 (5 - 5.0E+4) lx (2.2 - 2.2) % 818-MP-C801
6 (1 - 5.0E+4) lx (0.8 - 0.8) % 818-MP-C811
Quantity: Transmittance, regular spectral
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
(0.65 - 1) (0,0008 - 0,0008)
  • Wavelength (380 up to 1000) nm
  • Bandwidth < 3 nm
818-MP-C810
(0.3 - 0.65) (0,0041 - 0,0041)
  • Wavelength (380 up to 400) nm
  • Bandwidth < 3 nm
818-MP-C810
(0.3 - 0.65) (0,0013 - 0,0013)
  • Wavelength (400 up to 700) nm
  • Bandwidth < 3 nm
818-MP-C810
(0.3 - 0.65) (0,0017 - 0,0017)
  • Wavelength (700 up to 1000) nm
  • Bandwidth < 3 nm
818-MP-C810
(0.02 - 0.3) (0,0015 - 0,0015)
  • Wavelength (380 up to 400) nm
  • Bandwidth < 3 nm
818-MP-C810
(0.02 - 0.3) (0,00022 - 0,00022)
  • Wavelength (400 up to 1000) nm
  • Bandwidth < 3 nm
818-MP-C810
Quantity: Absorbance, regular, spectral
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
(0 - 0.19) (0.0003 - 5.0E-5)
  • Wavelength (380 up to 1000) nm
  • Bandwidth < 3 nm
818-MP-C810
(0.19 - 0.52) (0.0019 - 0.0052)
  • Wavelength (380 up to 400) nm
  • Bandwidth < 3 nm
818-MP-C810
(0.19 - 0.52) (0.0009 - 0.0019)
  • Wavelength (400 up to 700) nm
  • Bandwidth < 3 nm
818-MP-C810
(0.19 - 0.52) (0.0011 - 0.0025)
  • Wavelength (700 up to 1000) nm
  • Bandwidth < 3 nm
818-MP-C810
(0.52 - 1.7) (0.0022 - 0.0339)
  • Wavelength (380 up to 400) nm
  • Bandwidth < 3 nm
818-MP-C810
(0.52 - 1.7) (0.0003 - 0.0048)
  • Wavelength (400 up to 1000) nm
  • Bandwidth < 3 nm
818-MP-C810
(1.7 - 3) (0.03 - 0.0969)
  • Wavelength (380 up to 400) nm
  • Bandwidth < 3 nm
818-MP-C810
(1.7 - 3) (0.0017 - 0.0362)
  • Wavelength (400 up to 1000) nm
  • Bandwidth < 3 nm
818-MP-C810
Quantity: Wavelength
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
(400 - 1650) nm (2.0E-6 - 2.0E-6) (bezrozměrný)
  • CW Single frequency, Power level ˃ 0,05 mW
818-MP-C813
(400 - 1650) nm (1.0E-7 - 1.0E-7) (bezrozměrný)
  • CW Single frequency, Power level ˃ 0,05 mW
818-MP-C813
(400 - 1650) nm (1.0E-7 - 1.0E-7) (bezrozměrný)
  • CW Single frequency, Power level ˃ 0,05 mW
818-MP-C813
11 (200 - 1700) nm (0.2 - 0.2) nm 818-MP-C810
11 (200 - 1700) nm (0.2 - 0.2) nm 818-MP-C810
16 (800 - 1650) nm (4.0E-9 - 4.0E-9) nm 818-MP-C813
22 (365 - 923) nm (0.4 - 0.4) nm 818-MP-C806
Quantity: Spectral reflectance factor R
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
1 (0 - 100) % ((0,1 + 0,010R) - (0,1 + 0,010R)) % (abs.)
  • Wavelength (380 up to 460) nm
  • geometry 8º / t, 8º / d
818-MP-C802
1 (0 - 100) % ((0,12 + 0,008R) - (0,12 + 0,008R)) % (abs.)
  • Wavelength 465 up to 780 nm
  • geometry 8º / t, 8º / d
818-MP-C802
1 (0 - 100) % ((0,17 + 0,014R) - (0,17 + 0,014R)) % (abs.)
  • Wavelength (380 up to 780) nm
  • geometry 0º / 45º
818-MP-C802
1 (0 - 100) % ((0,1 + 0,010R) - (0,1 + 0,010R)) % (abs.)
  • Wavelength (380 up to 460) nm
  • geometry 8º / t, 8º / d
818-MP-C802
1 (0 - 100) % ((0,12 + 0,008R) - (0,12 + 0,008R)) % (abs.)
  • Wavelength 465 up to 780 nm
  • geometry 8º / t, 8º / d
818-MP-C802
1 (0 - 100) % ((0,17 + 0,014R) - (0,17 + 0,014R)) % (abs.)
  • Wavelength (380 up to 780) nm
  • geometry 0º / 45º
818-MP-C802
Quantity: Surface colour, colorimetric coordinate L*
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
2 (2 - 99) (0.35 - 0.35) % (abs.)
  • geometry 8º / t, 8º / d, 0º / 45º
818-MP-C802
2 (-110 - 110) (0.25 - 0.25) % (abs.)
  • geometry 8º / t, 8º / d, 0º / 45º
818-MP-C802
2 (2 - 99) (0.4 - 0.4) % (abs.)
  • geometry 8º / t, 8º / d, 0º / 45º
818-MP-C802
2 (-110 - 110) (0.3 - 0.3) % (abs.)
  • geometry 8º / t, 8º / d, 0º / 45º
818-MP-C802
Quantity: Surface colour, colorimetric coordinate Y
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
3 (0.3 - 100) (0.25 - 0.25) % (abs.)
  • geometry 8º / t, 8º / d, 0º / 45º
818-MP-C802
3 (0.002 - 0.7) (0.0005 - 0.0005) % (abs.)
  • geometry 8º / t, 8º / d, 0º / 45º
818-MP-C802
3 (0.002 - 0.8) (0.0005 - 0.0005) % (abs.)
  • geometry 8º / t, 8º / d, 0º / 45º
818-MP-C802
3 (0.3 - 100) (0.35 - 0.35) % (abs.)
  • geometry 8º / t, 8º / d, 0º / 45º
818-MP-C802
3 (0.002 - 0.7) (0.0007 - 0.0007) % (abs.)
  • geometry 8º / t, 8º / d, 0º / 45º
818-MP-C802
3 (0.002 - 0.8) (0.0007 - 0.0007) % (abs.)
  • geometry 8º / t, 8º / d, 0º / 45º
818-MP-C802
Quantity: Surface colour, colorimetric coordinate L
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
4 (2 - 99) (0.35 - 0.35) % (abs.)
  • geometry 8º / t, 8º / d, 0º / 45º
818-MP-C802
4 (0.002 - 0.6) (0.0005 - 0.0005) % (abs.)
  • geometry 8º / t, 8º / d, 0º / 45º
818-MP-C802
4 (2 - 99) (0.4 - 0.35) % (abs.)
  • geometry 8º / t, 8º / d, 0º / 45º
818-MP-C802
4 (0.002 - 0.6) (0.0008 - 0.0008) % (abs.)
  • geometry 8º / t, 8º / d, 0º / 45º
818-MP-C802
Quantity: Gloss
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
5 (0.1 - 150) GU (1.8 - 1.8) GU
  • geometry 20º, 60º, 85º
818-MP-C808
Quantity: Irradiance
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
7 (0.0001 - 1000) mW/cm2 (5 - 5) %
  • Wavelength (230 up to 470) nm
818-MP-C801
Quantity: Correlated colour temperature
Interní identifikátor Range Calibration and measurement capabilities Procedures
8 (2000 - 1.0E+4) K (10 - 85) K 818-MP-C801
Quantity: Perpendicular spectral transmittance
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
9 (0.1 - 1) (0.0012 - 0.0012)
  • Wavelength (200 up to 380) nm
818-MP-C810
9 (0.001 - 0.1) (0.0001 - 0.0001)
  • Wavelength (200 up to 380) nm
818-MP-C810
9 (0.6 - 1) (0.0008 - 0.0008)
  • Wavelength (380 up to 1000) nm
818-MP-C810
9 (0.3 - 0.6) (0.0041 - 0.0041)
  • Wavelength (380 up to 400) nm
818-MP-C810
9 (0.3 - 0.6) (0.00056 - 0.00056)
  • Wavelength (400 up to 700) nm
818-MP-C810
9 (0.3 - 0.6) (0.0017 - 0.0017)
  • Wavelength (700 up to 1000) nm
818-MP-C810
9 (0.02 - 0.3) (0.0015 - 0.0015)
  • Wavelength (380 up to 400) nm
818-MP-C810
9 (0.02 - 0.3) (0.00022 - 0.00022)
  • Wavelength (400 up to 1000) nm
818-MP-C810
9 (0.001 - 0.02) (0.0002 - 0.0002)
  • Wavelength (380 up to 400) nm
818-MP-C810
9 (0.001 - 0.02) (8.0E-5 - 8.0E-5)
  • Wavelength (400 up to 1000) nm
818-MP-C810
Quantity: kolmá spektrální absorbance
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
10 (0 - 1) (0.0005 - 0.0052) (abs.)
  • Wavelength (200 up to 380) nm
818-MP-C810
10 (1 - 3) (0.0004 - 0.046) (abs.)
  • Wavelength (200 up to 380) nm
818-MP-C810
10 (0 - =-LOG10(H157)) (0.0003 - 0.0006) (abs.)
  • Wavelength (380 up to 1000) nm
818-MP-C810
10 (0.22 - 0.52) (0.003 - 0.006) (abs.)
  • Wavelength (380 up to 400) nm
818-MP-C810
10 (0.22 - 0.52) (0.0004 - 0.0008) (abs.)
  • Wavelength (400 up to 700) nm
818-MP-C810
10 (0.22 - 0.52) (0.0012 - 0.0025) (abs.)
  • Wavelength (700 up to 1000) nm
818-MP-C810
10 (0.52 - 1.7) (0.0022 - 0.034) (abs.)
  • Wavelength (380 up to 400) nm
818-MP-C810
10 (0.52 - 1.7) (0.0003 - 0.0048) (abs.)
  • Wavelength (400 up to 1000) nm
818-MP-C810
10 (1.7 - 3) (0.0044 - 0.097) (abs.)
  • Wavelength (380 up to 400) nm
818-MP-C810
10 (1.7 - 3) (0.0017 - 0.036) (abs.)
  • Wavelength (400 up to 1000) nm
818-MP-C810
Quantity: Optical density D
Interní identifikátor Range Calibration and measurement capabilities Procedures
12 (0 - 4.5) (3.8 - 3.8) (abs.) 818-MP-C812
12 (0 - 4.5) (3.8 - 3.8) (abs.) 818-MP-C812
Quantity: Optical power
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
13 (1.0E-9 - 10) W (0.4 - 0.4) %
  • Wavelength (800 up to 920) nm
818-MP-C813
13 (1.0E-9 - 10) W (0.5 - 0.5) %
  • Wavelength (920 up to 960) nm
818-MP-C813
13 (1.0E-9 - 10) W (0.45 - 0.45) %
  • Wavelength (960 up to 1000) nm
818-MP-C813
13 (1.0E-9 - 10) W (0.47 - 0.47) %
  • Wavelength (1000 up to 1580) nm
818-MP-C813
13 (1.0E-9 - 10) W (0.6 - 0.6) %
  • Wavelength (1580 up to 1650) nm
818-MP-C813
Quantity: Optical attenuation
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
14 (0 - 65) dB (0.052 - 0.052) dB (abs.)
  • Wavelength (800 up to 1650) nm
818-MP-C813
Quantity: Linearity
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
15 (0 - 0.5) dB (0.004 - 0.004) dB
  • Power level 0 DBm up to 65 dBm
  • Wavelength (800 up to 1650) nm
818-MP-C813
Quantity: Brightness
Interní identifikátor Range Calibration and measurement capabilities Procedures
18 (1 - 3.0E+4) cd.m-2 (1.1 - 1.1) % 818-MP-C805
Quantity: Spectral irradiance
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
20 (0.65 - 300) nW.m-2.nm-1 (3.4 - 3.4) %
  • Wavelength (300 up to 400) nm
818-MP-C806
20 (0.65 - 300) nW.m-2.nm-1 (3 - 3) %
  • Wavelength (400 up to 1700) nm
818-MP-C806
20 (0.65 - 300) nW.m-2.nm-1 (4.5 - 4.5) %
  • Wavelength (1700 up to 2500) nm
818-MP-C806
Quantity: Spectral radiance
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
21 (1.12 - 10) nW.s-1.m-2.nm-1 (3.2 - 3.2) %
  • Wavelength (370 up to 800) nm
818-MP-C806
21 (1.12 - 10) nW.s-1.m-2.nm-1 (3.6 - 3.6) %
  • Wavelength (800 up to 1000) nm
818-MP-C806
21 (1.12 - 10) nW.s-1.m-2.nm-1 (3 - 3) %
  • Wavelength (1000 up to 1700) nm
818-MP-C806
21 (1.5 - 95) nW.s-1.m-2.nm-1 (3.2 - 3.2) %
  • Wavelength (370 up to 800) nm
818-MP-C806
21 (1.5 - 95) nW.s-1.m-2.nm-1 (3.6 - 3.6) %
  • Wavelength (800 up to 1000) nm
818-MP-C806
21 (1.5 - 95) nW.s-1.m-2.nm-1 (3 - 3) %
  • Wavelength (1000 up to 1700) nm
818-MP-C806
Quantity: Spectral integral parameters: substitute chromaticity temperature Tc
Interní identifikátor Range Calibration and measurement capabilities Procedures
23 (2000 - 1.0E+4) K (20 - 20) K 818-MP-C806
23 (2000 - 1.0E+4) K (20 - 20) K 818-MP-C806
Quantity: Spectral integral parameters: colour rendering index Ra
Interní identifikátor Range Calibration and measurement capabilities Procedures
23 (1 - 100) (1.2 - 1.2) (abs.) 818-MP-C806
23 (1 - 100) (0.7 - 0.7) (abs.) 818-MP-C806
Quantity: Spectral integral parameters: ligtht colour, colorimetric coordinate x
Interní identifikátor Range Calibration and measurement capabilities Procedures
23 (0.002 - 0.7) (0.0025 - 0.0025) (abs.) 818-MP-C806
23 (0.002 - 0.8) (0.002 - 0.002) (abs.) 818-MP-C806
23 (0.002 - 0.7) (0.0014 - 0.0014) (abs.) 818-MP-C806
23 (0.002 - 0.8) (0.001 - 0.001) (abs.) 818-MP-C806
Quantity: Spectral integral parameters: ligtht colour, colorimetric coordinate u´
Interní identifikátor Range Calibration and measurement capabilities Procedures
23 (0.002 - 0.6) (0.0017 - 0.0017) (abs.) 818-MP-C806
23 (0.002 - 0.6) (0.0015 - 0.0015) (abs.) 818-MP-C806
23 (0.002 - 0.6) (0.0009 - 0.0009) (abs.) 818-MP-C806
23 (0.002 - 0.6) (0.0006 - 0.0006) (abs.) 818-MP-C806