charge sensitivity (magnitude) |
|
-
frequency 20 Hz up to 1,0 kHz
|
|
CIPM MRA |
view |
|
charge sensitivity (magnitude) |
|
-
frequency >1,0 kHz up to 5 kHz
|
|
CIPM MRA |
view |
|
nábojová citlivost citlivost (magnituda) |
|
-
frequency 20 Hz up to 1,0 kHz
|
|
CIPM MRA |
view |
|
nábojová citlivost citlivost (magnituda) |
|
-
frequency >1,0 kHz up to 5 kHz
|
|
CIPM MRA |
view |
1 |
acceleration of mechanical vibration of sinusoidal wave |
|
-
frequency (0.1 up to 5000) Hz
|
internal and external metrology service |
accreditation |
view |
1 |
acceleration of mechanical vibration of sinusoidal wave |
|
-
frequency (5.0 up to 20) kHz
|
internal and external metrology service |
accreditation |
view |
2 |
vibration transducer sensitivity |
-
0.01 pC/m•s-2 - 1000 pC/m•s-2
|
-
frequency (0,1 up to 5000) Hz
|
internal and external metrology service, it is possible to specify in pC/g, resp. mV/g, where 1 g = 9,81 m.s-2 |
accreditation |
view |
2 |
vibration transducer sensitivity |
-
0.01 pC/m•s-2 - 1000 pC/m•s-2
|
-
frequency (5 up to 20) kHz
|
internal and external metrology service, it is possible to specify in pC/g, resp. mV/g, where 1 g = 9,81 m.s-2 |
accreditation |
view |
2 |
vibration transducer sensitivity |
-
0.01 mV/m•s-2 - 10000 mV/m•s-2
|
-
frequency (0.1 up to 5000) Hz
|
internal and external metrology service, it is possible to specify in pC/g, resp. mV/g, where 1 g = 9,81 m.s-2 |
accreditation |
view |
2 |
vibration transducer sensitivity |
-
0.01 mV/m•s-2 - 10000 mV/m•s-2
|
-
frequency (5 up to 20) kHz
|
internal and external metrology service, it is possible to specify in pC/g, resp. mV/g, where 1 g = 9,81 m.s-2 |
accreditation |
view |
2 |
vibration transducer sensitivity |
-
0.1 mV/m•s-1 - 10000 mV/m•s-1
|
-
frequency (0.1 up to 5000) Hz
|
internal and external metrology service, it is possible to specify in pC/g, resp. mV/g, where 1 g = 9,81 m.s-2 |
accreditation |
view |
2 |
vibration transducer sensitivity |
-
0.1 mV/m•s-1 - 10000 mV/m•s-1
|
-
frequency (5 up to 20) kHz
|
internal and external metrology service, it is possible to specify in pC/g, resp. mV/g, where 1 g = 9,81 m.s-2 |
accreditation |
view |
3 |
transfer function of amplifier and filter by simulator |
-
1.0E-7 V/V - 10000000 V/V
|
-
frequency (0.1 up to 100000) Hz
|
internal and external metrology service |
accreditation |
view |
3 |
transfer function of amplifier and filter by simulator |
|
-
frequency (0.1 up to 100000) Hz
|
internal and external metrology service |
accreditation |
view |
4 |
acceleration |
|
-
frequency (0.1 up to 100000) Hz
|
internal and external metrology service |
accreditation |
view |
4 |
speed |
|
-
frequency (0.1 up to 100000) Hz
|
internal and external metrology service |
accreditation |
view |
5 |
maximum value acceleration of mechanical shock of half-sine form |
|
|
internal and external metrology service |
accreditation |
view |
6 |
vibration frequency |
|
|
internal and external metrology service |
accreditation |
view |
7 |
Speed of road transportation vehicles and other objects |
|
|
internal and external metrology service |
accreditation |
view |
7 |
Speed of road transportation vehicles and other objects |
|
|
internal and external metrology service |
accreditation |
view |
8 |
revolution and pulse |
-
0.01 min-1 - 100000 min-1
|
|
internal and external metrology service, it is possible to specify in Hz |
accreditation |
view |
8 |
revolution and pulse |
|
|
internal and external metrology service, it is possible to specify in Hz |
accreditation |
view |
9 |
Linear motion velocity |
-
1.0E-5 m•s-1 - 1000 m•s-1
|
|
internal and external metrology service |
accreditation |
view |
10 |
Linear motion acceleration |
|
|
nternal and external metrology service |
accreditation |
view |